Description
The fibers, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire, sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member. Tubes (and fillers) are stranded around the strength member into a compact and circular cable core. The cable core is filled with the filling compound to protect it from water ingress, over which a thin PE inner sheath is applied. After the PSP is longitudinally applied over the inner sheath, the cable is completed with a PE outer sheath.
Characteristis
• Good mechanical and temperature performance
• High strength loose tube that is hydrolysis resistant
• Special tube filling compound ensure a critical protection of fiber
• Crush resistance and flexibility
• The following measures are taken to ensure the cable watertight:
• Steel wire is used as the central strength member
• Loose tube filling compound and 100% cable core filling
• APL moisture barrier
• PSP enhances moisture-proof
• Water-blocking material
Technical Parameters
Cable Type (Increased by 2 fibers) | Fibre Count | Tubes | Fillers | Cable Weight Kg/Km (Ref) | Tensile Strength Long/Short-Term(N) | Crush Resistance Long/Short Term(N/100mm) | Bending Radius Static/Dynamic(mm) |
GYTY53-2~6Xn | 2~6 | 1 | 5 | 160 | 1000/3000 | 1000/3000 | 12.5D/25D |
GYTY53-8~12Xn | 8~12 | 2 | 4 | 160 | |||
GYTY53-14~18Xn | 14~18 | 3 | 3 | 160 | |||
GYTY53-20~24Xn | 20~24 | 4 | 2 | 160 | |||
GYTY53-26~30Xn | 26~30 | 5 | 1 | 160 | |||
GYTY53-32~36Xn | 32~36 | 6 | 0 | 160 | |||
GYTY53-38~48Xn | 38~48 | 4 | 1 | 174 | |||
GYTY53-50~60Xn | 50~60 | 5 | 0 | 174 | |||
GYTY53-62~72Xn | 62~72 | 6 | 0 | 185 | |||
GYTY53-74~84Xn | 74~84 | 7 | 1 | 214 | |||
GYTY53-86~96Xn | 86~96 | 8 | 0 | 214 | |||
GYTY53-98~108Xn | 98~108 | 9 | 1 | 245 | |||
GYTY53-110~120Xn | 110~120 | 10 | 0 | 245 | |||
GYTY53-122~132Xn | 122~132 | 11 | 1 | 281 | |||
GYTY53-134~144Xn | 134~144 | 12 | 0 | 281 | |||
GYTY53-146~216Xn | 146~216 | 13~18 | 5~0 | 281 |
Optical Characteristics
Fiber Type | Attenuation(+20℃) | Bandwidth | Numerical Aperture | Cable Cut-off Waverlength λcc | ||||
@850 nm | @1300 nm | @1310 nm | @1550 nm | @850 nm | @1300 nm | |||
G.652 | -- | -- | ≤0.36dB/km | ≤0.22dB/km | -- | -- | -- | ≤1260 nm |
G.655 | -- | -- | ≤0.40dB/km | ≤0.23dB/km | -- | -- | -- | ≤1450 nm |
50/125 µm | ≤3.0dB/km | ≤1.0dB/km | -- | ≥500MHz·km | ≥500MHz·km | 0.200±0.015NA | -- | |
625/125 µm | ≤3.3dB/km | ≤1.0dB/km | -- | ≥200MHz·km | ≥500MHz·km | 0.275±0.015NA | -- |
Production Line
• 20 Sets Armoring Machines
• 8 Bow-type Optic Cable Production Lines
• 2 Indoor Cable Production Lines
• 8 Outdoor Cable Jacket Production Lines
• Professional Patch Cord Production Lines
Package and Transportation
Production Process
Material Inspection Report
Test Equipment
Testing Subject
• Fiber performance inspection
• Cable length
• External dimensions
• Tearing force
• Fiber eccentricity
• Minimum thickness inspection
• Fiber tightness inspection
• Steel wire testing
• Strength Member testing
• Clear and correct coding on cable
• To roll the cable neatly
• Flaming test
• Low friction test